User's Manual

MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc.
83
7.4.4.59 Rx DSP Receive failed
ID: 0x1019
Service: iden
Severity: major
Cause: Loss of Signal
System Reaction: SPAM Reset
Repair Action: Problem occurs when DSP stops receiving data from the RadioBlade.
Reseat or Replace RadioBlade.
7.4.4.60 RB initialization failure
ID: 0x101a
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: System Reset
Repair Action: RadioBlade failed to recover after 3 reset attempts. Replace RadioBlade
and report to RFN for further investigation.
7.4.4.61 RB initialization error
ID: 0x101b
Service: iden
Severity: major
Cause: Configuration Customization Error
System Reaction: Force RadioBlade to Register
Repair Action: Problem with RadioBlade setting up with wrong address.
7.4.4.62 Access point activation failed
ID: N/A
Service: wlan
Severity: minor
Cause: Equipment Malfunction
System Reaction: No action taken
Repair Action: Power Cycle or replace Data Host.