7.4.4.51 RB Error state
ID: 0x1011
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: RadioBlade Locked
Repair Action: System failed to read EEPROM calibration data from the RadioBlade.
Try a different slot or replace RadioBlade.
7.4.4.52 Logical Channel Setup error
ID: 0x1012
Service: iden
Severity: major
Cause: Communications Protocol Error
System Reaction: No Action Taken
Repair Action: Ignore if occurs while 1 or more BRs are being locked or system shuts
down. Otherwise report problem to RFN.
Note: There is currently a known issue in which this alarm may appear if
many BRs are being locked at the same time.
7.4.4.53 Tx DSP not responding
ID: 0x1013
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: SPAM Reset
Repair Action: Problem occurs if DSP stops transmitting data. Replace AIC.
7.4.4.54 Rx DSP not responding
ID: 0x1014
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: SPAM Reset
Repair Action: Problem occurs if DSP stops receiving data. Replace AIC.