Repair Action: This happens when the system is no longer able to communicate with
the Radio Blade. Reseat RadioBlade, Move to different slot, check RBS
connection to AIC. Replace RadioBlade.
7.4.4.37 APC out of Sync with NPC
ID: 0x1003
Service: iden
Severity: minor
Cause: Timing Problem
System Reaction: Force resynchronization of BPC+SPAM.
Repair Action: No action necessary if this alarm occurs after an alarm that results in a
SPAM Reset. No action necessary if occurs very infrequently. Otherwise
check for bad cables between AIC and BIC. Replace chassis.
7.4.4.38 APC failed to sync with NPC
ID: 0x1004
Service: iden
Severity: critical
Cause: Equipment Malfunction
System Reaction: System Reset
Repair Action: If alarm does not clear, check cabling between AIC and BIC. Replace
chassis.
7.4.4.39 DSP Tx Packet Failed
ID: 0x1005
Service: iden
Severity: critical
Cause: Loss of Signal
System Reaction: System Reset
Repair Action: Previously called DSP 1180 FLOODING. If happens at startup then
check the RB and try power cycling RB or RBS. Ignore if happens
infrequently. If alarm does not clear or alarm happens frequently, replace
chassis.
7.4.4.40 DSP Rx Packet Failed
ID: 0x1006
Service: iden