7.4.4.12 System Reset
ID: 0x0d
Service: asp
Severity: warning
Cause: Application Subsystem Failure
System Reaction: System Reset
Repair Action: This is the result of an alarm that causes a system reset. Investigate
cause from previous alarms.
7.4.4.13 “1 of 2” cooling fans has failed
ID: 0x0e
Service: asp
Severity: minor
Cause: Equipment Malfunction
System Reaction: No Action Taken
Repair Action: Inspect chassis fans for proper operation.
7.4.4.14 Temperature problem detected
ID: 0x11
Service: asp
Severity: major
Cause: Temperature Unacceptable (Major)
System Reaction: System May Shutdown
Repair Action: Alarm will be generated if temperature exceeds 49 C and will clear below
46 C. Inspect Unit environment.
7.4.4.15 Temperature problem detected
ID: 0x12
Service: asp
Severity: critical
Cause: Temperature Unacceptable (Critical)
System Reaction: System Reset
Repair Action: Alarm will be generated if temperature exceeds 52 C and will clear below
49 C. Inspect Unit environment.