User's Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
RadioFrame Networks, Inc. 91
7.6.1.3 Removal of RB:
When a RB is physically removed an event is generated in the System Manager Event Log
notifying the user about the RB removal. The RB controller will then de-register the RB from the
BR, which will result in locking the BR. A RB Insert event is generated when the RadioBlade is
inserted into the RBS.
7.6.1.4 Administratively locking a RB
Administratively locking a RadioBlade is when the RadioBlade lock icon on the RB Status page is
changed to lock. The following rules apply to this action.
1. If a locked RB is replaced, the new RB will be considered unlocked upon insertion. The
locking applies to a particular RB and not a particular Slot.
2. The locked RadioBlade will be preserved through a system reset.
3. RadioBlades in the disabled state will not be preserved through a system reset.
However, after a system reset, those blades that were originally in the disabled state due
to the effects of the locked RadioBlade and the particular policy will to go back into the
disabled state again.
7.7 Serial Log Upload Procedure
Complete this procedure before disconnecting and removing the BIC, AIC, RBS or an RF shelf
from the MC-Series System rack, or at the direction of RadioFrame Networks technical support.
1 Select the Diagnostics tab in System Manager, and then select the Serial Log Upload link.