User's Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
84 RadioFrame Networks, Inc.
Cause: Equipment Malfunction
System Reaction: SPAM Reset
Additional Info: dsp Id
Repair Action: Problem occurs if communication is lost to the Tx DSP. Reseat or replace SPAM.
Replace BPC.
7.4.4.42 Rx DSP not responding
ID: 4116
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: SPAM Reset
Additional Info: dsp Id
Repair Action: Problem occurs if communication is lost to the Rx DSP. Reseat or replace
SPAM. Replace BPC.
7.4.4.43 DSP unlock fail
ID: 4118
Service: iden
Severity: major
Cause: Equipment Malfunction
System Reaction: BR Disabled
Additional Info: None
Repair Action: Check version of the DSP SW.
Note: This alarm does not clear
7.4.4.44 Forward ISC version mismatch
ID: 4119
Service: iden
Severity: major
Cause: Version Mismatch
System Reaction: No Action Taken
Additional Info: ISC VER |or| RFN release version
Repair Action: This alarm occurs when the ISC version is newer than the current RFN SW
version. Verify that the RFN SW version is correct and verify that the ISC version is correct.
Note: This alarm does not have a clear