User's Manual

MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
82 RadioFrame Networks, Inc.
Additional Info: dspId or 0xff for hpi error
Repair Action: Check preceding alarms as to the cause of the SPAM reset. Reseat SPAM, if
problem persists, replace BPC.
7.4.4.35 Network memory shortage
ID: 4106
Service: iden
Severity: critical
Cause: Out of Memory
System Reaction: System Reset
Additional Info: cluster level
Repair Action: Internal problem with the network memory pool. Replace BPC.
7.4.4.36 Invalid RB Slot
ID: 4108
Service: iden
Severity: minor
Cause: Equipment Malfunction
System Reaction: Reset RadioBlade
Additional Info: None
Repair Action: Reseat RadioBlade. If problem still persists, replace RadioBlade or move to
another slot. If problem still persists, replace RBS.
7.4.4.37 DSP Tx null PDU
ID: 4110
Service: iden
Severity: minor
Cause: Loss of Signal
System Reaction: SPAM Reset
Additional Info: APC Mac address
Repair Action: This is a result of the DSP sending incorrect data to the RadioBlade. Ignore if
happening infrequently. Check for intermittent cable connections. Possibly a result of timing
problems on the NPC.
7.4.4.38 Interference/Calibration
ID: 4111