User's Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
72 RadioFrame Networks, Inc.
7.4.4.1 Alarm Overflow error
ID: 0001
Service: asp
Severity minor
Cause: Underlying Resource Unavailable
System Reaction: Alarms Were Discarded
Additional Info: None
Repair Action: This condition results from an error in the alarm manager handler in which there
is no longer enough space for the alarms. If this situation happens, most likely there is a
catastrophic failure that needs to be addressed first. Review previous alarms for root cause.
Note: This alarm does not have a clear.
7.4.4.2 Target Initialization Error
ID: 0002
Service: asp
Severity critical
Cause: Underlying Resource Unavailable
System Reaction: Equipment goes in Disabled State
Additional Info: None
Repair Action: The system was unable to load the software properly for the following reasons.
A) Proper SW version has not been loaded onto the board. Check SW revision and/or re-load
SW.
B) Reset Board
C) Board loader failing. Replace Board
7.4.4.3 Task Abnormally Terminated
ID: 0003
Service: asp
Severity major
Cause: S/W Program Abnormally Terminated
System Reaction: System Reset including RLIC
Additional Info: First 4 ASCII Text characters of the task that suspended
Repair Action: System should recover on its own. However, this alarm should be reported to
RFN for further investigation. Check corresponding board for any connection problems.
Note: This alarm does not have a clear.