Installation Guide
Table Of Contents
- Title
- Contents
- Introduction
- System Description
- Pre-Installation
- Receipt of Equipment
- Site Planning
- Main Rack and Supporting Hardware
- Remote ACUs
- RFUs
- RadioBlades
- RAPs
- URU
- Interconnecting Cabling
- Main Rack Configuration
- RF Planning
- Site Survey
- Alarm Configuration
- Tools Required
- Installation
- Equipment Commissioning
- iDEN Interface
- Power Plant
- RadioFrame System
- Coverage Validation
- Site Acceptance Guidelines
- RadioFrame System Functionality Test
- RadioFrame System iDEN Functionality Test
- Interconnect & Dispatch Setup & Voice Quality
- Packet Data Service Connection and Latency
- Short Message Service
- Handover and Cell Reselection
- Interconnect Connection Stability and SQE Performance
- Dispatch Connection Stability
- Idle SQE Testing and Validation
- System Self-Recovery Test
- Packet Data Stability and Throughput
- Validation of ‘Unable to Key BR’ Alarm
- Rectifier & AC Power Alarms
- iSC-3 Functionality Test
- RadioFrame System iDEN Functionality Test
- Connecting the RFS to the Customer LAN
- Operations and Maintenance
- Appendixes
Method of Procedure
Installation
70 RFN_3.1 Beta
Figure 20 Connect Port 1 on the front of the ACU to the specified port (1-8) on the
back of the NCU. Connect RFUs to Ports 1-8 on the back of the ACU.
4.3 URU
The maximum length of CAT 5 wire between RadioFrame System components is
100 meters (approximately 328’). The distance between any two components
can be extended by installing additional CAT 5 cabling and up to two URUs.
# of URUs Maximum CAT 5 Cable Length between RFS components
no URU 100 meters (approximately 328’)
1 URU 200 meters (approximately 656’)
2 URUs 300 meters (approximately 984’)
4.3.1 Installing a URU
Install Universal Repeater Units while wiring the RadioFrame System.
1 Find these items in each Universal Repeater Unit (URU) shipping container:
one URU, mounting screws, and one power cord with a 120VAC-to-negative
48VDC converter.
2 Place or mount the URU on any flat surface (see the following illustration).
The URU can be placed or mounted on any flat surface using the provided
mounting screws. The URU must be located within 12 feet of an approved
power source. Refer to the site documentation for the exact location of each
URU.