Installation Guide
Table Of Contents
- Title
- Contents
- Introduction
- System Description
- Pre-Installation
- Receipt of Equipment
- Site Planning
- Main Rack and Supporting Hardware
- Remote ACUs
- RFUs
- RadioBlades
- RAPs
- URU
- Interconnecting Cabling
- Main Rack Configuration
- RF Planning
- Site Survey
- Alarm Configuration
- Tools Required
- Installation
- Equipment Commissioning
- iDEN Interface
- Power Plant
- RadioFrame System
- Coverage Validation
- Site Acceptance Guidelines
- RadioFrame System Functionality Test
- RadioFrame System iDEN Functionality Test
- Interconnect & Dispatch Setup & Voice Quality
- Packet Data Service Connection and Latency
- Short Message Service
- Handover and Cell Reselection
- Interconnect Connection Stability and SQE Performance
- Dispatch Connection Stability
- Idle SQE Testing and Validation
- System Self-Recovery Test
- Packet Data Stability and Throughput
- Validation of ‘Unable to Key BR’ Alarm
- Rectifier & AC Power Alarms
- iSC-3 Functionality Test
- RadioFrame System iDEN Functionality Test
- Connecting the RFS to the Customer LAN
- Operations and Maintenance
- Appendixes
RadioFrame System
Pre-Installation
RFN_3.1 Beta 35
System Unit Weight
iSC-3 (2)
EAS
CSU
Power Plant Rectifier 72 lbs
(Power Plant 58 lbs) + (two Rectifiers at 7 lbs ea.)
Battery 600 lbs
(eight batteries at 75 lbs each)
3.3.4 Power
System Unit Power
RadioFrame System NCU
100-240 Volts AC, 47-63 Hz, 8-3.5A, or
Negative 52.5 ±.5 Volts DC, 11A
ACU
100-240 Volts AC, 47-63 Hz, 8-3.5A, or
Negative 52.5 ±.5 Volts DC, 11A
iDEN Interface iSC-3 (1)
Negative 40-60 Volts DC; 1.5 A
iSC-3 (2)
Negative 40-60 Volts DC; 1.5 A
EAS
Negative 40-60 Volts DC
CSU
Negative 40 Volts DC
Power Plant Rectifier
Input
Voltage
85 to 265 VAC (continuous)
45 to 70 Hz
Current
12 Amp maximum
The rectifier’s micro-controller adjusts
the output current to limit the input
current to allow each rectifier to be
plugged into a standard 115/230 VAC @
15 Amp IEC outlet.
Power Factor >90% for 20% to 100% loads
Output
Voltage
50.00 to 60.00 VDC
52.5 VDC Factory Set (default)
Regulation
± 1.0% (includes output o-ring diode)
Overvoltage
50.00 to 60.00 VDC
57.00 VDC Factory Set (default)
RED [FAIL] LED indication and shuts
down rectifier providing output
current.
Noise
<32 dBmC (voice frequency)
<100 millivolts-RMS (wide band)
<250 millivolts peak-to-peak