Installation Guide
Table Of Contents
- Title
- Contents
- Introduction
- System Description
- Pre-Installation
- Receipt of Equipment
- Site Planning
- Main Rack and Supporting Hardware
- Remote ACUs
- RFUs
- RadioBlades
- RAPs
- URU
- Interconnecting Cabling
- Main Rack Configuration
- RF Planning
- Site Survey
- Alarm Configuration
- Tools Required
- Installation
- Equipment Commissioning
- iDEN Interface
- Power Plant
- RadioFrame System
- Coverage Validation
- Site Acceptance Guidelines
- RadioFrame System Functionality Test
- RadioFrame System iDEN Functionality Test
- Interconnect & Dispatch Setup & Voice Quality
- Packet Data Service Connection and Latency
- Short Message Service
- Handover and Cell Reselection
- Interconnect Connection Stability and SQE Performance
- Dispatch Connection Stability
- Idle SQE Testing and Validation
- System Self-Recovery Test
- Packet Data Stability and Throughput
- Validation of ‘Unable to Key BR’ Alarm
- Rectifier & AC Power Alarms
- iSC-3 Functionality Test
- RadioFrame System iDEN Functionality Test
- Connecting the RFS to the Customer LAN
- Operations and Maintenance
- Appendixes
Method of Procedure
System Description
14 RFN_3.1 Beta
2.1.2.3 RadioFrame Unit (RFU)
The RadioFrame Unit serves as the access interface between signals received
from mobile terminals and the airlink processing performed in the ACU. The RFU
connects to the ACU via a single CAT 5 connection, and receives its power,
signals, and timing from the ACU. Each RFU holds up to 7 RadioBlades in
combination of: a maximum of 6 iDEN RadioBlades, a maximum of 3 RAPs.
Figure 7 RFU functional diagram.
2.1.2.4 iDEN RadioBlade (RadioBlade or RB)
Each iDEN RadioBlade provides a single RF channel transceiver supporting the
iDEN voice standard. Each RadioBlade contains an onboard omnidirectional
antenna and provides a coverage area of approximately 32,000 square feet
(nominal 100’ radius cell). Each RadioBlade inserts into a slot in the RFU.
Figure 8 iDEN RadioBlade functional diagram.
ACU, B
RB (1)
RB (1)
RB (1)
RB (1)
RB (1)
RFU
Backplane
RB (1)
REM
data, clock,
config, control,
timing and
power
Air Interface
Air Interface
RF
Section
Digital
Processing
Power
Timing
Ethernet
RFU Backplane