Alarm Description Action
BAD RB SLOT RB reported a slot number that is out of
range (1-8).
Replace either the RFU
or the RB.
BAD VGA 1180s received from the RB have a
consistently high Gain setting, even in the
absence of any signal indicating Rx
Calibration issues.
RIC will attempt to reset the RB three times,
and then generates a Calibration alarm.
BR ACTIVITY Not currently used. No action required.
BR ENABLE FAIL BR remained disabled for more than 30
minutes.
Causes the BR to go into permanent Error
mode and will not participate in further fault
recovery procedures.
BR STARTUP FAIL Not currently used. No action required.
CHNL SETUP ERR iSC channel setup (channelSetup) is invalid
or inconsistent.
Causes the BR to be de-keyed and to return
to LEI mode to restart the channel
allocations with the iSC.
COMMANDED
RESET
System Reset was initiated via System
Manager.
Causes a system reset.
COVERAGE HOLE One BR in a sector has fewer RBs than
other BRs in that sector.
The BR that is short of Radio Blades has
locked.
DHRB RESET A problem in the DHRB has caused it to
reset.
No action required.
DHRB TASK EXCEP Task Exceptions has occurred for some task
on the DHRB.
DHRB resets.
No action required.
DSP 1180 FLOOD The RB 1180 DSP address is flooding all
ports.
Sends a Stop Tx command to the RB and
causes a system reset.
DSP HPI ERROR Problem in accessing HPI interface for a
DSP.
If errors go beyond a threshold, SPAM is
reset.
DSP LOAD ERROR DSP software not found.
DSP was not initialized.
Check the ffs files etc.