User's Manual

RadioFrame System Method of Procedure GSM/802.11b
Operations and Maintenance
88 RadioFrame Networks, Inc.
Indication Possible failure Corrective action
Power and Status LEDs
for cards installed in
front or back of BCU are
not lit
no power to BCU
Verify that the power cord is
installed and properly seated.
Verify that the power source is
operational (120VAC or
–48VDC).
Contact Customer Support.
Status LED is red—top
front card only
timing source not
available
Connect the timing source.
Check all connections.
failed initialization
Reboot the system: unplug the
BCU, and plug it in again. Boot
up may take several minutes.
fan is not working
Verify that the fan is operational.
If the fan is not working, unplug
the BCU and contact Customer
Support.
Status LED is red—any
card
card is not operational
Remove and reseat card.
Contact Customer Support.
RJ45 port Link and
Activity LEDs are not lit,
or the Activity LED is not
blinking
connection is not being
made between RFS
components
For the affected port, verify that
all cabling between components
is properly connected.