User's Manual
GSM/802.11b RadioFrame System Method of Procedure
Pre-Installation
RadioFrame Networks, Inc.
35
3.6.6 Environment
• Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F)
• Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce maximum
operating ambient temperature by 2
o
C per 1000' to a maximum of 13000'
• Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F)
• Relative Humidity: 10-90% non condensing
• Shock: 40 g’s
• Vibration: Level 3 earthquake
• Keep product free from dust, wind, salt, liquids
3.6.7 Heat Load
• Not applicable
3.6.8 Cable and Connector Wiring
• Connector type is RJ-45.
• If directly cabling to the GSM RB without an antenna, use female SMA connectors.
• Appropriate color-coding and jack pair assignments should be followed when wiring
modular jacks, connectors, and cables.
Pin# Name Input / Output
1 Rx Ring Input
2 Rx Tip Input
4 Tx Ring Output
5 Tx Tip Output
Warning!
Crimp all connector wiring completely. Ensure that all crimps have fully
penetrated the protective coating on the wiring. Ensure that enough of the
protective coating is left in place to fit inside the connector. Failure to follow
these instructions may cause system failures to occur.
3.6.9 Output Power Level
• Nominal (maximum): 10 dB
• Can be adjusted downward in 2 dB increments.