User's Manual
GSM/802.11b RadioFrame System Method of Procedure
Pre-Installation
RadioFrame Networks, Inc.
33
3.5.3.4 Above
• Leave at least 1.25” between the top of the RFU and the ceiling or any overhead
structure.
• Leave at least 3” below the RFU.
3.5.4 Weight
• 12 lbs (fully loaded with 6 RadioBlades/RAPs)
3.5.5 Power
• Negative 36-56 Volts DC, 0.8A
3.5.6 Grounding
• No additional grounding required
3.5.7 Environment
• Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F)
• Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce maximum
operating ambient temperature by 2
o
C per 1000' to a maximum of 13000'
• Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F)
• Relative Humidity: 10-90% non condensing
• Shock: 40 g’s
• Vibration: Level 3 earthquake
• Keep product free from dust, wind, salt, liquids
3.5.8 Heat Load
• 85 BTUs
3.5.9 RF Exposure
To comply with FCC RF exposure requirements, GSM antennas must be installed to
provide at least 8 inches (20 cm) separation from all persons, with antenna gain not
exceeding zero (0) dBi.
3.5.10 Cable Support
• CAT-5 wiring to ACU