User's Manual

GSM/802.11b RadioFrame System Method of Procedure
Pre-Installation
RadioFrame Networks, Inc.
33
3.5.3.4 Above
Leave at least 1.25” between the top of the RFU and the ceiling or any overhead
structure.
Leave at least 3” below the RFU.
3.5.4 Weight
12 lbs (fully loaded with 6 RadioBlades/RAPs)
3.5.5 Power
Negative 36-56 Volts DC, 0.8A
3.5.6 Grounding
No additional grounding required
3.5.7 Environment
Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F)
Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce maximum
operating ambient temperature by 2
o
C per 1000' to a maximum of 13000'
Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F)
Relative Humidity: 10-90% non condensing
Shock: 40 g’s
Vibration: Level 3 earthquake
Keep product free from dust, wind, salt, liquids
3.5.8 Heat Load
85 BTUs
3.5.9 RF Exposure
To comply with FCC RF exposure requirements, GSM antennas must be installed to
provide at least 8 inches (20 cm) separation from all persons, with antenna gain not
exceeding zero (0) dBi.
3.5.10 Cable Support
CAT-5 wiring to ACU