User's Manual
GSM/802.11b RadioFrame System Method of Procedure
Operations and Maintenance
RadioFrame Networks, Inc.
95
System Manager Alarm Description Action
operation.
FAN2 ALARM Chassis FAN2 is malfunctioning. Check chassis fans for proper
operation.
FFS PARTITION Board booted from wrong partition.
May indicate problem with the files on
boot partition.
Verify software versions for each
partition in System Manager.
GSMRB LOSS Communication with the GSM
RadioBlade has been lost.
The corresponding BR is locked and
all associated RBs have stopped.
LAPD LINK FAIL The LAPD connection between the
BR and the iSC has been lost.
The BR will try to re-establish the
LAPD and sends a state change trap
to iSC.
Check the iSC connection.
LOST RFU All the GSM RBs and Datahosts in an
RFU have been lost.
Check the RFU connections, etc.
NET POOL ERROR The free Mblock cluster has gone
below 40 on a BPC or APC, the
threshold for
APC_NETPOOL_LOWMARK or
NPC_NETPOOL_LOWMARK.
Causes a system reset.
OVERTEMP A chassis has overheated. Check the chassis for proper
operation.
PEER LOSS Communication with a board has
been lost.
RIC has detected a PEER LOSS from
the BLIC.
Causes a system reset, unless the
cause is a iRAP, which self resets.
Check board connections. If frequent,
capture alarms and serial logs and
submit to RFN.
PLL LOCK A RIC or BLIC PLL went out of lock.
The BLIC locks and de-key all BRs,
and then sends a state change trap to
the iSC.
ROM MISMATCH Board boot version is not the same as
the BLIC.
SPAM FAILED Lost DSP PDUs have exceeded
threshold.
SPAM is reset.
SW VER MISMATCH Board software version is not the
same as the BLIC.
SYSTEM RESET Alarms that result in a system reset
cause this alarm, except for the BLIC.
All BRs and boards are locked and
reset except the BLIC.