User's Manual

4-1
DrillTrack BoreLogger Instructions
The Borelogger can be activated or deactivated in the set-up menu (see page 3-1)
To activate the Borelogger access the set-up mode and set the BORELOG option to ON.
To enter Borelog Mode press and hold the key. A list of functions for the logging will appear:
GO, DEL, END, UP
Scroll through using the or key, press key to confirm selection.
To start a log, set the log to GO.
When in the “Four-Arrows Locate screen with depth displayed. Press the key to transmit the
depth to the Data View. The screen will then display “LOG, press key again within 5 seconds to
confirm. The display changes to a new screen, an audible beep confirms the action of logging the
data, showing “LOG” and the stored rod number
To add a simulated locate point, in the “Two Arrow Steering” screen press the key, the display will
show ADD and LOG with a rod number, press key again to confirm the addition of the simulated
locate point.
To delete one log back, hold down the key to enter the Borelog Mode.
Select DEL and press INFO to show the last stored rodnumber. Press the key within 5 seconds to
delete the last log. A double beep will confirm deletion. When finished deleitng, press and hold
key and select GO to return to logging data.
When finished with logging, it is important that the log is manually ended. Do this by entering into the
Borelog Mode and select END. Upon completion of the Borelog date and time will be stored.
To upload the Borelog data, enter the Borelog Mode and select UP and press key to activate the
data transfer. A rotating clock will appear to confirm that the unit is waiting to upload the log to the PC.
After uploading is completed, turn off the Receiver.