User's Manual

3-1
DrillTrack Operating Instructions
Before starting
Fit new alkaline batteries in the DataSonde observing the correct polarity. The Receiver must be fitted with 6
x 1.5V’C’ size alkaline (LR14) or 3 Rechargeable Battery Packs. For the correct battery type refer to the
Technical Specification section on DataSondes in this user manual .
Switch the DataView on and using the magnetic mounts, place it on the Drilling machine in a comfortable
viewing position for the Drilling machine operator.
Lock and secure the receiver antenna outriggers into position.
Setup the DrillTrack Receiver.
The Receiver Setup Menu allows the user to initially set the Receiver to the required measurements.
While the Receiver is turned off, press and hold the key, then press the key to switch the unit on and
enter the Setup Menu.
Using the and the key to select the required option, and press the key to confirm the selected
option and to go to the next screen.
Repeat this procedure for all the Setup Menu screens.
The following screens with options will be displayed in the Setup Menu:
- Depth measurement in Metric or Imperial.
- Tilt angle measurement in Percentage of grade or Degrees.
- DataSonde Temperature measurement in Celsius or Fahrenheit.
- Numeric signal strength Activated or Deactivated.
- Selection of type and frequency of DataSonde
- Locate orientation.
- Borelogger System Activated or Deactivated.
- DataView selection