User's Manual
PDL-4 A.C.ID-M System (with GPS) User Guide
Page 20
If the tip of the SmartProbe-2 is outside the
Confirmation Zone, but not further than 4 ft from the
target cable, the 'Reposition the SmartProbe-2'
screen is displayed at one of two zoom levels
(maximum horizontal displacements of 2 ft or 4 ft).
'Position Estimate' is displayed across the screen.
If the probe tip is close to or within the Confirmation
Zone, and the A.C.ID-M signal is noisy, the
SmartProbe-2 will transmit an intermediate result and
continue measurement. The PDL-4 displays
'Rechecking A.C.ID-M' and a progress bar.
If the SmartProbe 2 has been placed too far away
from the target cable the “Cable out of range” screen
will be displayed indicating direction and approximate
position of the cable.
If the tip of the SmartProbe-2 is within the
confirmation box but at 180
0
to the cable the
PDL-4
display will show “Current Direction Wrong".
If A.C.ID-M confirmation is not achieved the PDL-4
will display a 'Not Confirmed'.
Penetration Bar
Assembly
Handle and Penetration Rod
Holding the Handle/Safety Lock assembly (1) with
the handle uppermost, ensure that the Safety Lock
(2) is turned fully anti-clockwise. This locks the
upper part of the rod to the handle.
Screw the Penetration Rod (3) to the Handle/Safety
Lock assembly and tighten using two
7
/
8
" AF
spanners.
Depth Indicator
Place the Outer Sleeve (4) on a hard surface with the
wider inner diameter uppermost then place the Disc
(5) on top of the Outer Sleeve. Press down firmly
and evenly on the Disc, forcing it to fit into the groove
around the Outer Sleeve.
With their wider ends uppermost, place the two
Collets (6) on the Penetration Bar and locate them in
the desired depth groove. Fit the 'O' ring (7) over the
Collets ensuring it is correctly seated in the grooves
provided.
With the Disc end uppermost, pass the Outer
Sleeve/Disc assembly up the Penetration Bar. Push
the Outer Sleeve/Disc assembly over the Collets/'O'
ring until the Disc end of the Outer Sleeve is flush
with the upper end of the Collets.
Operation
Safety Lock
To release the Safety Lock, rest the tip of the
Penetration Bar on the ground and, holding the
handle, rotate the Safety Lock
1
/
4
turn clockwise.
1
2
3
7
6
5
4