Instructions / Assembly
PG 18
PG 18
Humidier -
To use the CT80 internal humidistat to control an external
humidier unit, connect it as shown. Connect the H
terminal to the control leg of the humidier relay. This
allows H to turn the humidier ON and Off.
DeHumidier -
To use the CT80 internal humidistat to control an external
dehumidier unit, connect it as shown. Connect the DH
terminal to the control leg of the dehumidier relay. This
allows DH to turn the dehumidier ON and OFF.
Fresh Air -
The Fresh Air feature uses the EX relay to control a bafe
on a fresh external air source. Connect the 24VAC bafe
to C and EX terminals.
H or DH
To HUMIDIFIER
or
DEHUMIDIFIER
RELAY
RH
FOR EXTERNAL HUMIDIFIER
or DEHUMIDIFIER USING
HVAC SYSTEM's 24
VAC
H or DH
R
C
CT80
FURNACE
POWER
24VAC
H or DH
To HUMIDIFIER
or
DEHUMIDIFIER
RELAY
RH
USING 24VAC ADAPTER
H or DH
R
C
CT80
FURNACE
POWER
AC
ADPT
FOR EXTERNAL HUMIDIFIER
or DEHUMIDIFIER USING
BAFFLE
RH
FOR FRESH AIR BAFFLE
EX
R
C
CT80
FURNACE
POWER