Instructions / Assembly

PG 16
PG 16
W
n
Y
n
R
G
Multi-stage Heat and Multi-stage Cool
The CT80 can handle up to 3 stages of HEAT and 2 stages of COOL.
STEP 1 - Connect the W, W2 and W3 wires to the W terminals. This
connects the stages of HEAT.
STEP 2 - Connect the Y and Y2 wires to the Y terminals.
This connects the stages of COOL.
STEP 3 - STEP 5 - Connect the R (or RH) wire to the RH
terminal. This connects the power.
STEP 4 - Connect the G wire to the G terminal. This connects the fan.
STEP 5 - Connect the C wire to the C terminal.
Your HVAC system is now connected to the CT80.
Please Go To Page 6
Heat Pump (heat/cool) without Auxiliary Heat
STEP 1 - Connect O wire to the O terminal or B wire to the B. This connects the change-over valve.
If you have both O and B - connect only the O wire to the O terminal and DO NOT connect B to B
terminal (see wire reference under Trane for B wire terminal).
STEP 2 - Connect the Y wire(s) to the Y terminal(s).
This connects the compressor (stages).
STEP 3 - Connect the R (or RH) wire to RH.
This connects the power.
STEP 4 - Connect the G wire to the G. This connects the fan.
STEP 5 - Connect the C wire to the C terminal.
Your HVAC system is now connected to the CT80.
Please Go To Page 6