Installation manual
Function 2: CO lines  IVX 128 
E.4 
Function 212: T1 programming 
This function allows you to program the trunks and line parameters for the DLC12 card. The system 
will identify the number of DLC12 cards installed (one or two) and allow you to scroll through the 24 
channels on each port card. 
T1 PROGRAMMING 
Function 2121: CO line programming 
Software has identified the port card type installed as a DLC12 card. The display will show the fol-
lowing information: the first line will show the port card number, the type of card, the COs available 
to program and a 
D
 or 
N
 for day or night mode. The second line will show the CO currently selected 
and the circuit that is being programmed. If multiple COs are selected, then the last CO selected is 
displayed. All DSS LEDs will glow red until selected for programming. 
You can select from the first set of 16 COs, and then press the scroll key to select from the remaining 
eight CO lines on the first DLC12 card. Scrolling again will allow you to select the 16 COs on a second 
DLC12 card if one is installed, and scrolling again will allow you to select from the eight remaining 
COs. If there is only one DLC12 card installed, then scrolling will return you to the first 16 COs. Select 
the COs to program alike and press 
#
 to confirm. The LED will glow green and then, after a CO is 
programmed, the LED will glow amber. The programming of the first CO should default forward for 
the remaining COs selected. After the selected COs are programmed, the LED will glow amber. 
For example: if the port card in the third slot is a DLC12 card, the display will be: 
PC3 T112 13-36 D 
CO22 CIRCUIT 10>  
Use the scroll keys to select the 
trunk type emulation
: either 
E&M DNIS/DID, E&M, LOOP START
 or 
GROUND START
. Press 
#
 to confirm. (Default is 
E&M DNIS/DID
.) 
TRUNK EMULATION 
E&M DNIS/DID > 
If 
LOOP START 
or 
GROUND START
 is selected:
Continue with the outbound CO line groups and answer ring assignment. 
If 
E&M DNIS/DID
 is selected:
The lines are routed to the DNIS/DID table. After the E&M programming is complete, select the 
outbound CO line groups. 
If 
E&M
 is selected:
The lines are routed to the answer ring assignment. After the E&M programming is complete, select 
the outbound CO line groups and the answer ring assignment. 
To 
complete
 the programming of the E&M trunks selected: 
1. 
Use the scroll keys to select the 
outgoing signal type
 — 
WINK START, IMMEDIATE START
 or 
DIAL 
TONE START
. Press 
#
 to confirm. Default is 
WINK START
. 
OUTGOING SIGNAL 
DIAL TONE START>  