Installation manual
Hardware overview/installation IVX 128
B.8
Hardware installation
Site location
As with most electronic equipment, the environmental considerations for this site need to observe
good common sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the 66 blocks
and 110VAC power.
The location should be no further than 1,000 feet from the farthest station.
Ambient room temperature must be 40
0
–80
0
(F.), and relative humidity no higher than 90%.
Note:
Do not
place the equipment or station runs near high voltage electrical equipment or electri-
cal lines susceptible to high voltage surges from air conditioner compressors, etc.
The system and supporting components should be mounted to a half-inch (or greater) plywood
backboard. A typical-installation Base Cabinet I layout is shown below.