User`s guide
32 33
Object Lockout
Transmissions for locked out objects are ignored for
all scan list. Four lockout types are available:
• Temporary – The object is locked out until the
scanner is turned off. When the scanner is turned
on again, temporary lockouts are removed. A
flashing lowercase “l” indicates a temporary lockout.
• Permanent – The object is locked out until
you unlock it. An uppercase “L” indicates a
permanent lockout.
• Talkgroup Lockout – Used with wildcard TGRP
objects. This locks out a specific talkgroup, but
the wildcard TGRP remains active.
• Search Lockout – Lock out up to 250 undesired
frequencies that are found during searches.
To lock out an object:
• While the object is active, press L/OUT.
• To apply permanent lockout, press FUNC and
then L/OUT.
• To lock out a talkgroup, press the TGL/O
softkey.
Temporary
Lockout
G
04-0237 CONV plD
FM 153.950000
FIRE CT:127.3
G
04-0237 CONV pLD
FM 153.950000
FIRE CT:127.3
Permanent
Lockout
To remove a lockout:
1. Navigate to the object using the 4-direction
keypad.
2. Press L/OUT.
3. To remove a permanent lockout, press FUNC
and then L/OUT.
To find objects that are locked out:
1. Press PROG.
2. Press the EDIT softkey.
3. Press the FIND softkey.
4. Press the L/Out softkey.
5. Press the NEXT softkey to find the next locked
out object.
To edit the Search Lockout List:
1. Press PROG
2. Press the GLOB softkey
3. Scroll down to SRCH L/Outs and press SEL.
4. To manually add to the list, scroll to an empty
spot and enter the frequency.
5. To remove a frequency, press the Del softkey.
6. To clear the entire list, press FUNC and then the
Del softkey.