Owner`s manual
6
Installation
If you have a Cat. No. 49-459 alarm sys-
tem, connect the dialer’s
ALARM
termi-
nals to terminals 50 and 51 on that
system.
If you have a Cat. No. 49-485 alarm sys-
tem, connect the dialer’s
ALARM
termi-
nals to Terminals 28 and 29 on that
system.
3. Connect one of the
FIRE
terminals on
the dialer to your alarm system’s fire ter-
minal.
4. Connect the dialer’s other
FIRE
terminal
to your alarm system’s ground terminal.
If you have a Cat. No. 49-485 alarm sys-
tem, connect the dialer’s
FIRE
terminals
to terminals 27 and 28 on the alarm sys-
tem.
If you have a Cat. No. 49-459 alarm sys-
tem, connect the dialer’s
FIRE
terminals
to terminals 55 and 56 on the alarm sys-
tem.
Connecting to Contact Closure
N.O. (Normally Open) Terminals
Follow these steps to connect the dialer to
any terminals on your alarm system that pro-
vide a contact closure when the alarm is trig-
gered.
1. Connect the
AUX POWER +
terminal on
the side of the dialer to one of your
alarm system’s contact closure termi-
nals.
2. Connect one of the
ALARM
terminals on
the dialer to your alarm system’s other
contact closure terminal.
If you have a Cat. No. 49-451 or 49-454
alarm system, connect the dialer’s
AUX
POWER +
terminal to Terminal 11, then
connect one of the dialer’s
ALARM
ter-
minals to Terminal 12.
If you have a Cat. No. 49-485 alarm sys-
tem:
For burglar alarm activation,
connect the
dialer’s
AUX POWER +
terminal to Termi-
nal 32, then connect one of the dialer’s
ALARM
terminals to Terminal 33.
For fire alarm activation,
connect the
dialer’s
AUX POWER +
terminal to Termi-
nal 30, then connect one of the dialer’s
FIRE
terminals to Terminal 31.
If you have a Cat. No. 49-459 alarm sys-
tem:
For burglar alarm activation,
connect the
dialer’s
AUX POWER +
terminal to Termi-
nal 50, then connect one of the dialer’s
ALARM
terminals to Terminal 51.
For fire alarm activation,
connect the
dialer’s
AUX POWER +
terminal to Termi-
nal 55, then connect one of the dialer’s
FIRE
terminals to Terminal 56.
3. Use a short piece of wire to connect the
AUX POWER –
terminal on the dialer to
the remaining
ALARM
or
FIRE
terminal
on the dialer.
CONNECTING POWER
Connecting to AC Power
Cautions:
You must use a Class 2 power
source that supplies 12V DC
and delivers at least 200 mA.
Its center tip must be set to positive and
its plug must fit the dialer's
DC 12V
jack.
The supplied adapter meets these spec-
ifications. Using an adapter that does
not meet these specifications could
damage the dialer or the adapter.
!