12. Divide the displacement between the vertical cur-
sors (the value shown in the box) by the
value in the timebase (time-per-division), then
multiply the result by the number of degrees per
division calculated in Step 11.
Note: The relative amplitude of the measured sig-
nals does not affect the phase measurement if the
signals are centered around the grid’s center hori-
zontal line.
Single Sweep Waveform Measurements
You can measure a waveform that occurs only once
without repeating, such as a noise spike that occurs
when you turn on an electronic device.
Follow these steps to measure a single sweep wave-
form.
1. Continuously press the Menu button until the trig-
ger
mode appears on the display.
2. Set the input coupling switch to
GND
.
3. Connect the
GROUND
(0 volt) wire to the signal
source’s ground or reference level.
4. Rotate
Zero Level
to vertically position the trace to
a convenient line on the grid overlay.
Time
Zero Reference Line
22-310.fm Page 44 Friday, August 6, 1999 12:26 PM