Owner`s manual
25
4. Rotate
Zero Level
to position the zero reference
line:
a.On the bottom of the computer display until the
indicator appears on the screen to get the
maximum positive (+) measurement, or
On the top of the computer display until the in-
dicator appears on the screen to get the maxi-
mum negative (–) measurement.
b.Slowly re-adjust
Zero Level
in the opposite
direction until just past the point where the or
indicator disappears from the oscilloscope
screen on the computer’s display.
Notes
:
• The grid must be turned on)
• The reference line on the oscilloscope display
should be set to just above the bottom line or
just below the top line on the grid.
• The position on the grid overlay depends on
the input signal’s polarity and amplitude, but
should be chosen so the trace lies along one of
the grid overlay’s major divisions. If the trace is
widened by stray interference, ground the
probe body near the point being measured.
The trace position is the voltage reference line
and all voltage measurements are read in
respect to this line. (Do not adjust the vertical
positioning control after the reference is estab-
lished.)
5. Set
INPUT COUPLING
to
DC
.
6. If it was necessary to ground the tip (see Step 3
note), remove the tip from the ground or reference
voltage. This readies the tip so you can use it to
make a measurement.
22-310.fm Page 25 Friday, August 6, 1999 12:26 PM