User`s guide

66
Trunk Scanning
Setting the Disconnect Tone Detect Function
When the Motorola disconnect tone detect
function is disabled, the scanner looks for squelch
before returning to the control channel instead
of waiting for the disconnect tone. Only in rare
instances will you need to adjust the default
settings. The condition to return to control
channels depends on whether the signal is
present or not.
1. Press FUNC + MAN/MENU to open Menu Mode.
2. Select Trunk Option, then press ENT/PGM. Press
T or S to select select a bank, then press
ENT/PGM.
3. Select MOT, and press ENT/PGM.
4. Select Set End Code, and press ENT/PGM.
5. Select Yes or Ignore, and press ENT/PGM.
Note: If you set the squelch so you hear
a hissing sound when you set ignore,
the scanner will remain on the voice
channel, even when a disconnect tone is
transmitted or there is no signal at all.
EDACS Talk Groups
Selecting the EDACS Talk Group ID Format
Your scanner can enter or display EDACS talk
groups in decimal format (1-2047).
1. Press FUNC + MAN/MENU to open Menu
Mode.
2. Select Trunk Option, then press ENT/PGM. Press T
or S to select a bank, then press ENT/PGM.
3. Select EDCS, and press ENT/PGM.
4. Select EDCS ID Format, and press ENT/PGM.
3. Select AFS Format or Decimal Format, and press
ENT/PGM.