User`s guide

59
Trunk Scanning
Setting the Base Frequency, Offset Channel, and
Spacing for 800 MHz Custom
To properly track Motorola 800 MHz Custom
trunked systems, you must enter the base frequency,
offset channel and spacing for each system.
1. Press FUNC + MAN/MENU to enter the
Menu Mode.
2. Select Trunk Option press ENT/PGM.
3. Select the desired bank and press ENT/PGM.
4. Select Motorola system, and press ENT/PGM.
5. Select 800MHz CH Plan, and press ENT/PGM.
6. Select Custom Item, and press ENT/PGM.
7. Select Custom Range, and press ENT/PGM.
8. Select Base Freq, and press ENT/PGM.
9. Use the number keys and to enter a Lower
Frequency, then press ENT/PGM.
10. Use the number keys and to enter an Upper
Frequency, then press ENT/PGM.
11. Select Offset, and press ENT/PGM.
12. Use the number keys and to enter an Offset
Channel, then press ENT/PGM.
Note: You can input within a range of 0 -
1023 for 800 MHz Custom trunked system.
13. Select Spacing, and press ENT/PGM.
14. Select a Spacing Frequency, then press ENT/
PGM].
Note: You can only select within a range
of 12.5 – 100 kHz, and 12.5 kHz multiples.
15. Press CL. The scanner returns to the previous
screen.
16. If you want to program another Custom
Range, repeat steps 7 through 15.