User`s guide

21
Searching
Searching
Use the search function to find active frequencies.
While doing a chain, fine tune, or service bank
search, press •/DELAY to turn the delay on or off.
While doing a chain, fine tune, or service bank
search, set the scanner to skip data signals (such
as fax or modem signals) if you want to search
only for audio (voice) signals (see “Skipping Data
Signals” on p. 38).
Chain Search
This feature lets you search through preset
frequency ranges. You can also program a range.
There are three modes within this feature: Chain
Search Mode, Chain Search Pause Mode, and
Program Band Select Mode.
The preset frequency ranges are:
Bank Frequency (MHz) Step (kHz)
0 25.0000-27.9950 5
1 28.0000-54.0000 5
2 137.0000-174.0000 5
3 216.0000-224.9950 5
4 225.0000-399.9875 12.5
5 400.0000-512.0000 6.25
6 764.0000-775.9875 12.5
7 794.0000-805.9875 12.5
8 806.0000-956.0000 12.5
9 1240.0000-1300.0000 12.5
Starting Chain Search
1. Press SRCH, and then repeatedly press SRCH
until SR6 appears at the top of the display.
2. Press 0 – 9 to enable or disable the search
bank being searched.
Note: At least one bank needs to be entered.