Service manual
3
7) Make a test cut to verify that the borders are measuring accurately. It may be
necessary to move the sensor and/or magnet on the bracket slightly in order to
achieve the desired border accuracy (see below*). Minor calibration (<1/32”),
corrections may be made in Advanced Settings, Borders, Home X or Y Axis.
* These are the general guidelines for moving an X or Y axis home sensor to correct for
inaccurate border dimensions:
X- Axis (Horizontal) Border measures:
Too Small; Move sensor left (facing rear of machine)
Too Large; move sensor right ( “ “ “ “ )
Y- Axis (Vertical) Border measures:
Too small; move sensor bracket up, or magnet downward
Too large; move sensor bracket down, or magnet upward
Move the sensor or magnet by the exact amount of the border error; i.e. + or - 1/16”.
X-axis limit switch
X-axis Home sensor
Loosen bracket screw and move sensor left or right to adjust borders