Service manual
1
REMOVAL / INSTALLATION PROCEDURE
F-6100 ELECTRONIC CONTROL ENCLOSURE
Removal Procedure
1. Turn off power to the F-6100 system.
2. Disconnect the power cord from the wall outlet/power strip, and from the center rear outlet of
the control enclosure.
3. Disconnect the eight (8) round AMP
connectors (P201-208) from the top
rear panel of the enclosure. Turn the
locking collar on the AMP connector
counter-clockwise and pull the plug
out straight to disengage. (Do not
lose or misplace the rubber O-rings,
as they will be needed for re-
installation of the new enclosure.)
4. Disconnect the connectors (monitor,
keyboard, mouse, printer, if present) from
the lower rear panel of the enclosure.
Loosen thumbscrews on the monitor and
mouse connectors and pull straight out.
5. If present, disconnect modem and
Ethernet cables, also on lower rear
enclosure panel. Release the plastic
retaining clip on each and pull out
straight.