3
Once the Axis Operation window has been opened, click the Relative Mode button (1),
then the Enable radio button (2), and the Clear Fault button (3), as shown above. Verify
that the Increment value is set to 5202 (1 inch of X or Y axis movement), and that the
Velocity and Acceleration are set to 15000 and 30000 respectively. These are default
settings only, and may be altered to check for specific motion control problems.
To operate the X-axis motor (left and right movement), first release the Emergency Stop
knob and press the Enable button on the controller. Click the Right arrow (4) to move the
head/gantry to the right by 1 inch. Each click of the Right or Left arrow buttons will move
the machine by one inch (5202 steps) in that direction. Increasing the Increment number
will move the gantry by a greater distance, i.e. 52020 = 10 inches.
1
2
3
4