Service manual

5
Belt Uncoupling and Reversing Unit Repair
1) Mark the top edge of the cutting head
mounting plate with a pencil, then remove
the 4 flat head bolts with a 5mm Allen
wrench. Note: check for any shim
washers behind the mounting plate, and
note the location(s).
2) Remove the top bearing wipe
assembly by removing the 3
screws with a 3mm Allen wrench.
(Remove the Y-axis home
sensor magnet bracket from the
top wipe assembly first, and
mark its location) Slide the cable
ties and wires off the mounting
post.
Remove Y-home magnet bracket from here first
Remove 4 flat head bolts