X – Axis Reversing Unit Replacement
Reversing units may require replacement in the event of failed or missing internal
cartridge bearings. All four X-axis reversing units are mounted to the machine frame
extrusions in a similar manner, however, each will require a different amount of
disassembly of the machine in order the access the suspect unit. This procedure covers
replacement of the top-left (from front), reversing unit, which is the most accessible X-
axis reversing unit.
1) Move the gantry to the center of the
machine frame, and lock it into
position with four angle brackets;
one on each side of the top and
bottom ends of the gantry. Use
spring-loaded T-nuts and flat head
M5 bolts to mount the brackets
securely to the frame.
2) Remove the cable carrier from the
carrier bracket, and the bracket from the rear of the top adapter block.