Handbook
Table Of Contents
- 1 Introduction
- 2 ClearFill®Star System Description
- 3 System Design Guidelines
- 3.1 CDMA Basics (in preparation)
- 3.2 Required information for system design
- 3.3 Design step by step
- 3.4 Estimated RF Coverage per RRH
- 3.5 Right-sizing - the beacon feature (in preparation)
- 3.6 Capacity demand - number for BSIs (in preparation)
- 3.7 System Architecture
- 4 System Installation
- 4.1 General
- 4.2 System Installation (Hardware Installation)
- 4.3 Installation Radio Remote Head (RRH)
- 4.4 Installation Gigabit Ethernet Switch (GES)
- 4.5 Installation Base Station Interface (BSI)
- 4.6 Installation NMS Server (Hardware)
- 4.7 Commissioning of NMS
- 5 NMS Overview
- 5.1 Introduction
- 5.2 Starting the NMS
- 5.3 Tools and Utilities of NMS server
- 5.4 Main Window of NMS Application Client (structure)
- 5.5 The NMS client functionality
- 5.6 Right Click Menus
- 5.7 RRH Configuration
- 5.8 BSI Configuration
- 6 Configuration Management
- 7 System Supervision
- 8 Remote Management and Supervision
- 9 Operational used cases/Maintenance
- 10 System Specifications and Technical Data
- 11 Conformance Statements
- 11.1 United States
- 11.1.1 Introduction
- 11.1.2 Federal Communications Commission (FCC)
- 11.1.3 FCC Part 15 Class A
- 11.1.4 RF approval
- 11.1.5 IEC product safety conformance
- 11.1.6 Indoor applications
- 11.1.7 Antenna exposure
- 11.1.8 Radiofrequency radiation exposure Information
- 11.1.9 Packaging collection and recovery requirements
- 11.1.10 Recycling / take-back / disposal of products and batteries
- 11.2 Canada
- 11.1 United States
- 12 Appendix
ClearFill Star CDMA
1100187 Rev. 1.0
Page 62 of 152
4.7.3.4 VLAN Configuration of GES
The ClearFill®Star system uses the tag based VLAN mode.
There are three different tags used in the ClearFill®Star network:
NMS
Voice
Data
The three tags have to be configured in every GES. Also the support of every VLAN port has
to be setup for every port of the GES.
Therefore it is mandatory that a good documentation of the installed hardware is available. It
should have been created during the hardware installation process (see section 4.2).
For every GES it has to be known
Which ClearFill®Star network elements are connected to which port?
Which sector are the network elements supposed to be operating in?
The VLAN tags are chosen to reflect the sector.
Procedure to set a GES to support STP:
1. Open Microsoft Internet Explorer.
2. Enter the address “http://192.168.1.1” in the address window.
3. Login to the switch by using
Username: admin
Password: admin
4. Click on VLAN in the left hand side menu.
5. Click on VLAN Mode in the appearing submenu.
6. Select Tag-Based in the upper drop down menu.
7. Click on Apply.
8. Click on Tag-based Group in the left hand side menu.
9. Select default: VLAN tag
10. Click on Edit.
11. Set VLAN Name to: NMS
12. Set VID to: 1
13. Set SYM-VLAN to: Enable (via drop down menu)
14. Set GVRP Propagation to: Disable (via drop down menu)
15. Activate: every port (1-12)
16. Click on Apply.