Handbook
Table Of Contents
- 1 Introduction
- 2 ClearFill®Star System Description
- 3 System Design Guidelines
- 3.1 CDMA Basics (in preparation)
- 3.2 Required information for system design
- 3.3 Design step by step
- 3.4 Estimated RF Coverage per RRH
- 3.5 Right-sizing - the beacon feature (in preparation)
- 3.6 Capacity demand - number for BSIs (in preparation)
- 3.7 System Architecture
- 4 System Installation
- 4.1 General
- 4.2 System Installation (Hardware Installation)
- 4.3 Installation Radio Remote Head (RRH)
- 4.4 Installation Gigabit Ethernet Switch (GES)
- 4.5 Installation Base Station Interface (BSI)
- 4.6 Installation NMS Server (Hardware)
- 4.7 Commissioning of NMS
- 5 NMS Overview
- 5.1 Introduction
- 5.2 Starting the NMS
- 5.3 Tools and Utilities of NMS server
- 5.4 Main Window of NMS Application Client (structure)
- 5.5 The NMS client functionality
- 5.6 Right Click Menus
- 5.7 RRH Configuration
- 5.8 BSI Configuration
- 6 Configuration Management
- 7 System Supervision
- 8 Remote Management and Supervision
- 9 Operational used cases/Maintenance
- 10 System Specifications and Technical Data
- 11 Conformance Statements
- 11.1 United States
- 11.1.1 Introduction
- 11.1.2 Federal Communications Commission (FCC)
- 11.1.3 FCC Part 15 Class A
- 11.1.4 RF approval
- 11.1.5 IEC product safety conformance
- 11.1.6 Indoor applications
- 11.1.7 Antenna exposure
- 11.1.8 Radiofrequency radiation exposure Information
- 11.1.9 Packaging collection and recovery requirements
- 11.1.10 Recycling / take-back / disposal of products and batteries
- 11.2 Canada
- 11.1 United States
- 12 Appendix
ClearFill Star CDMA
1100187 Rev. 1.0
Page 46 of 152
3.4.2.2 Uplink
For the mobile, the output power and dynamic range was assumed as shown in Table 8.
Cell
GSM-
850
PCS GSM-
1900
Maximum mobile output
power
27 dBm
33 dBm
23 dBm 30 dBm
Minimum mobile output
power
-50
dBm
5 dBm
-50 dBm 0 dBm
Mobile Antenna loss -6 dBi
-6 dBi
-6 dBi -6 dBi
Body loss 2 dB
2 dB
2 dB 2 dB
Mobile dynamic 77 dB
28 dBm
73 dB 30 dB
Table 8 Power levels of mobiles
The schematic scenario for calculation of the UL dynamic range is illustrated in Figure 23
Scenario for UL reception power level calculation
.
BTS ClearFill.Star1
System DynamicMobile Dynamic
Coverage Radius
Figure 23 Scenario for UL reception power level calculation