The following typical wall attenuations were observed:
Type Attenuation [dB]
Thin concrete wall - 10cm (4 inches) 5
Thick concrete wall - 13cm (5 inches) 13
External wall front with windows 8
External wall front without windows 10
Porous concrete 4
Dry wall, sheetrock 1-2
Wood structure, wood door 1
Glass 2
Concrete floor 13
Brick Wall - 10cm (4 inches) 4
Brick Wall - 6cm (2 inches) 3
Partitions metal 1-2
Plastic structure 0.5
Glass with metal grid 8
Table 2 Typical attenuation for different materials (source: Wireless Valley)