Handbook
Table Of Contents
- 1 Introduction
- 2 ClearFill®Star System Description
- 3 System Design Guidelines
- 3.1 CDMA Basics (in preparation)
- 3.2 Required information for system design
- 3.3 Design step by step
- 3.4 Estimated RF Coverage per RRH
- 3.5 Right-sizing - the beacon feature (in preparation)
- 3.6 Capacity demand - number for BSIs (in preparation)
- 3.7 System Architecture
- 4 System Installation
- 4.1 General
- 4.2 System Installation (Hardware Installation)
- 4.3 Installation Radio Remote Head (RRH)
- 4.4 Installation Gigabit Ethernet Switch (GES)
- 4.5 Installation Base Station Interface (BSI)
- 4.6 Installation NMS Server (Hardware)
- 4.7 Commissioning of NMS
- 5 NMS Overview
- 5.1 Introduction
- 5.2 Starting the NMS
- 5.3 Tools and Utilities of NMS server
- 5.4 Main Window of NMS Application Client (structure)
- 5.5 The NMS client functionality
- 5.6 Right Click Menus
- 5.7 RRH Configuration
- 5.8 BSI Configuration
- 6 Configuration Management
- 7 System Supervision
- 8 Remote Management and Supervision
- 9 Operational used cases/Maintenance
- 10 System Specifications and Technical Data
- 11 Conformance Statements
- 11.1 United States
- 11.1.1 Introduction
- 11.1.2 Federal Communications Commission (FCC)
- 11.1.3 FCC Part 15 Class A
- 11.1.4 RF approval
- 11.1.5 IEC product safety conformance
- 11.1.6 Indoor applications
- 11.1.7 Antenna exposure
- 11.1.8 Radiofrequency radiation exposure Information
- 11.1.9 Packaging collection and recovery requirements
- 11.1.10 Recycling / take-back / disposal of products and batteries
- 11.2 Canada
- 11.1 United States
- 12 Appendix
ClearFill Star CDMA
1100187 Rev. 1.0
Page 142 of 152
10.1.3.1.1 Uplink Parameter Specification (Linear Operation)
CELL800 / PCS1900
Input power level
range
-65 to –90 dBm at maximum gain
-49 to –80 dBm at minimum gain
Nominal gain 61 dB for input power level range
Manual gain setting
61 dB to 37 dB in 1 dB steps
(the gain setting has to be performed in the RRH)
Output power level @
max. Input and max.
gain
-4 dBm ±1.5 dB
Output power level at
extreme temperature
-4 dBm ± 2.5 dB
max. composite output power level
independent to number of
connected RRHs. Assumed
PAR=10dB
EVM at BSI output
port
< 10 %
Noise figure < 12 dB at room temperature and 61 dB gain,
< 23 dB at room temperature and 37 dB gain
The system noise figure will increase as more RRHs are
added to a sector.
ACPR > 45 dBc @ 30kHz
Return Loss > 9 dB @ all RF connectors
In-band noise floor
and spurious without
input signal
<-38.5 dBm / 1.25MHz @ maximum gain
<-51.5 dBm / 1.25MHz @ minimum gain
Table 13 Uplink Parameter Specification