10.1.3.1.1 Uplink Parameter Specification (Linear Operation)
CELL800 / PCS1900
Input power level
range
-65 to –90 dBm at maximum gain
-49 to –80 dBm at minimum gain
Nominal gain 61 dB for input power level range
Manual gain setting
61 dB to 37 dB in 1 dB steps
(the gain setting has to be performed in the RRH)
Output power level @
max. Input and max.
gain
-4 dBm ±1.5 dB
Output power level at
extreme temperature
-4 dBm ± 2.5 dB
max. composite output power level
independent to number of
connected RRHs. Assumed
PAR=10dB
EVM at BSI output
port
< 10 %
Noise figure < 12 dB at room temperature and 61 dB gain,
< 23 dB at room temperature and 37 dB gain
The system noise figure will increase as more RRHs are
added to a sector.
ACPR > 45 dBc @ 30kHz
Return Loss > 9 dB @ all RF connectors
In-band noise floor
and spurious without
input signal
<-38.5 dBm / 1.25MHz @ maximum gain
<-51.5 dBm / 1.25MHz @ minimum gain
Table 13 Uplink Parameter Specification