6.2.3 GES
The GES is configurable over an own HTTP menu. This menu can be reached by simply
opening a browser (e.g. Microsoft Internet Explorer) and entering an “http://” followed by the
IP address of the GES.
It is also accessible by using the ClearFill®Star Application Client. And change to the menu
Application->Network Maps->Switches. Right click on the switch symbol and select (HTTP
device). The browser will open automatically, showing the HTTP menu of the switch.
To set up the GES for ClearFill®Star operation please follow the initial installation guide as
described in section 4.4 Installation Gigabit Ethernet Switch (GES). The use of other settings
is not advisable.
6.2.4 BSI
The following BSI functions are controlled via NMS:
6.2.4.1 Channel allocation
The channel allocation is done only once during initial sector configuration. The sector
configuration is described in chapter 6.2.1.
To change the channel allocation the sector has to be cleared by using the template
described in section 5.5.3.1.4. Afterwards the sector configuration has to be redone with
updated channel data.
6.2.4.2 Assignment to a BTS sector (VLAN setting)
The assignment to a BTS sector is done only once during initial sector configuration. The
sector configuration is described in chapter 6.2.1.
To change the assignment to a BTS sector the sector has to be cleared by using the
template described in section 5.5.3.1.4. Afterwards the sector configuration has to be redone
with updated channel data.
6.2.4.3 Summing function activation and deactivation
The setting is done automatically, no user interaction is necessary.
6.2.4.4 Switching between CELL and PCS band
The switching between CELL and PCS band is done only once during initial sector
configuration. The sector configuration is described in chapter 6.2.1.
To change the band from CELL to PCS or vice versa the sector has to be cleared by using
the template described in section 5.5.3.1.4. Afterwards the sector configuration has to be
redone with updated band values.