User's Manual
10
Part Number: J24004
Drawing Control: JD16049
Testing at Celwave has shown that two, 12 V batteries in series, rated at 7 AH will power the 48660 for greater than
30 minutes.
ENVIRONMENTAL CONSIDERATIONS
Operating Temperature: -30
o
C to +50
o
C
Operation over 60
o
C voids warranty.
Operation at case temperatures over 50
o
C should be limited to 200 hours per year.
Humidity: Non-condensing up to 95% relative for 0
o
C to 50
o
C within full specified data.
PERIODIC MAINTENANCE
There is little maintenance in the 48660 Intelli BDA. As long as the unit is kept away from extreme temperatures,
and moisture, it will provide long-term, carefree operation. Periodically, check the two type "N" RF connections for
corrosion, strain damage, and tightness. Periodically, check the AC or DC power connections for integrity.
The 48660 Intelli BDA enclosure is intended for weather protected applications. Venting the enclosure increases the
reliability but provides an entrance for moisture. It is also advisable to avoid a location with continuous high levels
of sunlight exposure and/or excessively dirty and dusty environments.
Description Manufacturer Part Number Notes
Mating connector for DC
Connector
Switchcraft TA3F or TA3FL
Fuses--External AC and
Internal DC
Various Various 5 x 20mm 3.15 A Fast Acting
Telco Interconnect Various RJ-11 Plug Std Tip & Ring Wired