User's Manual

9
Part Number: J24004
Drawing Control: JD16049
discontinue service. When practical, they will notify you in advance of this disconnection. If advance notice is not
feasible, you will be notified as soon as possible. When you are notified, you will be given the opportunity to correct
the problem and be informed of your right to file a complaint with the FCC. Contact your telephone company if you
have any questions about your phone line. In the event repairs are ever needed on the intelliBDA, Celwave or an
authorized representative of Celwave should perform them. For information contact:
Celwave-Corvallis
4100 SW Research Way
Corvallis Oregon 97333-1066
.
RF CONNECTIONS
The primary RF connections are made via two type "N" female connectors. The connector labeled "BASE
STATION" must be connected to the antenna/system pointing towards the base station. The connector labeled
"SERVICE AREA" must be connected to the antenna/system pointing into the service area.
AC / DC POWER
The 48660 comes with a standard 6 ft. US type NEMA 5-15P 3-wire male plug with phase, neutral, and safety
ground wires. AC power is only used to supply a high-efficiency 24 VDC switching power supply. This supply has
been thoroughly tested by Celwave for temperature capability, modulation effects, and harmonic coupling into the
RF circuitry. All internal components are powered by 24 VDC.
{Power supply listings: UL E100527 Vol. 6 (USA), CSA LR64950-40 (Canada), TUV R9472032 (Europe), VDE
NR84964 (Germany).} ****CHECK NEW LISTINGS!!!********
The 48660 Intelli BDA is fused to prevent further damage should the BDA fail. The fuse located in the AC
receptacle housing. To replace, unplug power cord and with finger, apply slight downward pressure on the fuse door
while pulling out. The door will open and the fuse can then be replaced with a 3.15 Amp 5 x 20 mm type fuse or
equivalent. Never replace with a higher amperage rated fuse! This may cause damage to the 48660 Intelli BDA and
void warranty.
WARNING: 120 VAC can be lethal. Never insert conductive objects into any opening.
The 48660 Intelli BDA has a 3 pin DC connector on the front panel. This can be used to supply DC power between
+20 V and +28 V for battery back up applications. If AC power is present, the 48660 will not draw any current from
this connector. Once AC power is removed, the Intelli BDA senses if there is a voltage present at this port and
begins to draw current. If the voltage at this port ever drops below +20 Volts DC, the 48660 will turn itself off until
AC power is restored.
The DC input is protected against short circuit, over voltage and reverse polarity conditions. It cannot be used to
charge batteries. This DC input is fused with the same fuse as used in the AC Power receptacle housing. To access
the DC fuse, first remove AC and DC power from the Intelli BDA, open shroud and with a fuse puller or equivalent
tool, remove fuse located in bottom right corner of the Digital Board (See Figure X.X). Replace with a 3.15 Amp 5
x 20mm fuse or equivalent. Never replace with a higher amperage rated fuse!!! This may cause damage to the 48660
Intelli BDA and void warranty.