If the message has to be sent to a group of terminals, select Group ID
It is possible to set how many times sending the alarm message consecutively by selecting Repetitions ,
and how frequently (seconds) by selecting Interval
It is possible to set the timeslot the warning messages will be sent by selecting TS 1 or TS 2 .
Select Write to activate the current settings.
Alarm
Event
I/O 1
Active I/O 1 contact
I/O 2
Active I/O 2 contact
Supply undervoltage
Voltage supply under the minimum value
Supply overvoltage
Voltage supply over the maximum value
Ethernet link
Link Ethernet disrupted
MST/SAT sync
Loss of synchronism between Master and Satellite
Environmental temperature
Environmental temperature out of range
TX Temperature
TX temperature out of range
RX lock
RX unlocked
Connection to master
Connection with working Master (Satellite only)
Satellite registration
Registration of new Satellite (Master only)
Satellite deregistration
Deregistration of new Satellite(Master only)
Satellite lost
Unreachable satellite(Master only)
GSM/GPRS not working
GSM/GPRS connection not working (only for Base Stations equipped with I/O
board and GSM/GPRS module)
Noise on the RF channel
Not yet active
Emergency call on TS1
An emergency call is ongoing on TS1
Emergency call on TS2
An emergency call is ongoing on TS2
DSP generic failure
Internal alarm on DSP module
TX generic failure
Internal alarm on TX module
RX generic failure
Internal alarm on RX module
TRX alarm
TRX alarm 1 (strong alarm) is enabled