User's Manual
DMR repeater 24/01/2011 Versione 1.1
Documento Riservato - non divulgabile senza autorizzazione
Pag. 44 / 55
To enable these functions click on Set ; All the parameters will assume their original values if you restart the
device, unless you perform a Save in eep operation (see the DMR LAYER CONFIGURATION paragraph).
6.2.2.10 ANALOG VOTER
Clicking on RA-DMR
RadioConfiguration
Analogical voter the following form will appear:
This form allows the user to set the analogical voter inputs (in the section Voter parameters ),
In the Voter parameters section you can:
∞ choose the signal sources for the analogical voting and the related setting time,
∞ set the hold time for the voted source (that is the minimum time before source changing),
∞ set the switch time (that is the minimum time between source changing after hold time expiration),
∞ set the signal hysteresis (that is the signal threshold for a valid candidate source).
You can set these parameters specifying the numbers in the section on the right: Initial setting
time [ms] is the searching time for the best signal initially, Hold time [ms] is the time the voted source
is maintained. Switch time [ms] is the time step after which a different input can be voted as the “best”,
Hysteresys [dB] is a threshold: if another signal is Hysteresys [dB] better than the currently voted
one, that signal become the new voted one.
To enable these functions click on Set ; All the parameters will assume their original values if you restart the
device, unless you perform a Save in eep operation (see the DMR LAYER CONFIGURATION paragraph).