In both cases you must choose the connection mode (IP LAN or COM1-COM9 serial connection)
A serial connection requires the setting of the following parameters:
∞ port speed (600 bps – 115,2 Kbps);
∞ bit per character (7 – 8);
∞ parity (nothing, even, odd);
∞ stop bit (1 – 2)
∞ possibility of activating the HW control flow (RTS/CTS)
∞ possibility of activating a connection through a modem rather than a direct connection (if this is the
case you must specify the phone number and the Modem Reset button will be activated).
The requested parameters for a LAN connection are only the IP address and the TCP port (normally port 4000)
necessary for the remote control:
You can also specify the remote control address of the device (if you do not select the item
Define Address (hex) the broadcast address will be used)
Note: Normally you need not to specify the remote control address. You must specify it if you want to
connect to the remote device through the RF channel of the local one (future feature), or if you have a
Base Station configured as 1+1 and you want to connect to a TRX even if it isn’t the active one.
If you have made a simple change of the parameters of an existing profile, the program automatically require
saving the modified parameters: