User's Manual

24
\Vn Extended Result Code This command defines the attributes of the CONNECT
result code.
\V0 Connect result code will be appended with the DTE (Serial Port Host
Interface) Speed. For example CONNECT 9600 indicates the Serial
Interface is 9600bps.
\V1 Connect result code will reflect the RF data link speed. For example
CONNECT RF9600 indicates that the RF data link is at 9600.
&W Save current configuration Issuing AT&W command will save current DTE
speed, specific AT commands and S registers into the modules NVRAM (Non
Volatile Random Access Memory) This means the module will revert to the
saved settings whenever the module is powered Off/On or reset with either the
ATZ command or Pin 16 is toggled. The following command and registers can be
stored. This command also saves the DTE speed that the AT&W command is
issued.
Storable Commands: \Tn, %An, %Fn, %Mn, %Sn, &Dn, Bn, \In
Storable S Registers: S0, S7, S18
Z Soft reset - This command will cause the module to reset the AT commands to the
values stored in the modules memory (See the &W command).