Radicom Research, Inc.
Table of Contents RC3000A-E Product Introduction 3 RC3000A-E Functional Architecture 4 RC3000A-E module Features 5 RC3000A-E Product Mechanical Dimensions 7 Using RC3000AMB to connect to Your System 8 Hardware interface A. UART interface B. Audio interface C. USB interface D. I2C interface E. SPI interface F. GPIO interface G. PCM interface 11 11 12 13 14 14 14 14 H.
RC3000A-E Product Introduction Thank you for purchasing Radicom Research’s RC3000A-E product. We are committed to providing you quality service and technical support. The RC3000A-E is the perfect solution for integrating WCDMA applications into many different types of embedded hosts or remote equipment. This product is fully self-contained and requires only a serial TTL interface from your product, SIM card and cellular signal access to provide you with state of the art data, fax, and voice operation.
RC3000A-E Functional Architecture GPS Antenna DDR GPS RF NAND Flash WCDMA/GSM Antenna Single Chip GSM/WCDMA RF Frontend Processor GSM PA Transceiver Vbat* WCDMA PA Power Management SIM UART Audio I2C USB GPIOs ADC LDO SPI PCM Interrupt Status LED Power On Reset Vbat* Vbat* VCTCXO 19.2MHz Regulator 32.
RC3000A-E Features • • • • • • • • • • • • RC3000A: Dual-Band UMTS/HSDPA 850/1900MHz, Quad-Band GSM/GPRS/EDGE 850/900/1800/1900MHz Supported embedded LUA Script Language A-GPS: MS-Based, MS-Assisted supported Support for Data transfer: HSDPA: Max. 3.6Mbps(DL) WCDMA: Max. 384Kbps(DL), Max. 384Kbps(UL) EDGE Class: Max. 236.8Kbps(DL), Max. 118Kbps(UL) GPRS: Max. 85.6Kbps(DL), Max. 42.8Kbps(UL) CSD: • GSM data rate 14.4Kbps • WCDMA data rate 57.
Output power Audio features (optional) Serial interface USB Phonebook management SIM application toolkit Real Time Clock Timer function Physical characteristics Firmware upgrade PCM USB Driver support Temperature range Certification GPRS. User can choose preferred mode. • UMTS 850/1900: 0.25W • UMTS 900/2100: 0.25W • GSM850/GSM900: 2W • DCS1800/PCS1900: 1W Speech codec modes: • Half Rate (ETS 06.20) • Full Rate (ETS 06.10) • Enhanced Full Rate (ETS 06.50 / 06.60 / 06.
RC3000A-E Mechanical Dimensions RC3000A-E view: Side View: 7
Using RC3000A-E connecting to Your System Product picture and Function 1. RC3000A Module 2. RF RPSMA connector 3. SIM card socket 4. SPI/I2C/GPIO/ADC interface socket (please see note1 for pins out orientation) 5. 3.5mm Ear phone jack 6. 3.5mm Microphone jack 7. GPS RF SMA connector 8. IDC 10 RS232 socket (please see note2 for pins out orientation) 9. Mini USB connector 10. USB_5V power on indicator 11.
Note 1: SPI/I2C/GPIO/ADC interface socket pins out definition: 1: ADC_2 2: ADC_1 3: GPIO_1 4: Ground 5: I2C_SDA 6: SPI_CS_N 7: GPIO_2 8: SPI_MOSI_DATA 9: I2C_SCL 10: SPI_MISO_DATA 11: VDD+3.
`Launch RC3000A-E Product 1. Connect antenna/SIM card/IDC 10 RS232 cable to ○ 1 RF RPSMA connector/ 3 SIM card socket/ ○ 8 IDC 10 RS232 socket accordingly ○ 2. Plug in ○ 9 Mini USB connector 5V power 3. ○ 11 USB_5V power on indicator (blue LED) will turn on 4. ○ 10 Network status indicator (green LED) will be on after blue LED turns on 5 seconds, RC3000AMB is entering power on sequence at this stage. 5. When Docklight screen shows below message which means the UART port is established: 6. 2014/1/3 14:51:44.
The RC3000A-E provides an UART (universal asynchronous serial transmission) port. It consists of a flexible 7-wire serial interface. The module is as the DCE (Data Communication Equipment) and the client PC is as the DTE (Data Terminal Equipment). AT commands are entered and serial communication is performed through UART interface. The application circuit is in the following figures.
low logic level to inform the master (client PC). It will stay low until the master clears the interrupt event with AT command. If Full Modem is used to establish communication between devices, the pin “RI” is another operation status. Initially it keeps high, when a voice call or CSD call comes, the pin “RI” will change to low for about 5900ms, then it will return to high level for 100ms. It will repeat this procedure until this call is answered or hung up.
txFilter rxGain rxVol stGain rxFilter Input PCM 13-tap filter parameters, 7 values Digital gain of output signal after summation of sidetone Digital Volume of output signal after speech decoder, before summation of sidetone and DAC Digital attenuation of sidetone Output PCM 13-tap filter parameters, 7 values 0…65535 --- MATLAB calculate AT+CTXFTR 0, Mute, 1…65535 -84…+12dB 20 * log (rxGain/16384) AT+CRXGAIN dbm 300…300 -300…300dbm AT+CLVL AT+CVLVL AT+CRXVOL 0, Mute, 1…65535 -96…0dB 20 * log
D. I2C Interface: I2C is used to communicate with peripheral equipment and can be operated as either a transmitter or receiver, depending on the device function. Use AT Commands “AT+CRIIC and AT+CWIIC” to read/write register values of related peripheral equipment connected with I2C interface. Both SDA and SCL are bidirectional lines, connected to a positive supply via a pullup resistor respectively. When the bus is free, both lines are high.
This ADC is 12 bit successive-approximation circuit, and electronic specification is shown in the following table. Electronic Characteristics: Specification Min Typ Max Resolution 12 Differential nonlinearity -4 +4 Integral nonlinearity -8 +8 Gain Error -2.5 +2.5 Offset Error -4 +40 Input Range GND 4.4V Input serial resistance 2 Input capacitance Power-down to wakeup 53 9.6 19.2 Unit Comments/Conditions Bits LSB Analog Vdd = ADC LSB reference 2.
Global Positioning System (GPS) RC3000A merges GPS satellite and network information to provide a high-availability solution that offers industry-leading accuracy and performance. This solution performs well, even in very challenging environment conditions where conventional GPS receivers fail, and provides a platform to enable wireless operators to address both location-based services and emergency mandates.
compared to the assisted modes. However, it requires no server interaction and works out of network coverage.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Industry Canada statement: This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada.
Safety Rules and Recommendations READ CAREFULLY Be sure the use of this product is allowed in the country. It is responsibility of the user to enforce the country regulation and the specific environment regulation. The product has to supply a stabilized voltage source and the wiring may have to conform to local security and fire prevention regulations. .
Antenna Requirements WARNING: Using an antenna other than the type approved for use with this product requires the finished product, with the module and new antenna type installed to be tested to comply with all sections of FCC Part 15 requirements! Every module has to be equipped with a proper antenna with specific characteristics.
• The Antenna must not be co-located or operated in conjunction with any other antenna or transmitter. Antenna shall not be installed inside metal cases. • Antenna shall be installed also according Antenna manufacturer instructions.
SIM (Subscriber Identity Module) Card Information To access a cellular network you must purchase a compatible SIM card. The GSM modules have a SIM card slot located on the bottom of the PCB. The SIM card has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Please read the SIM manufactures instructions prior to installing. Do not insert or remove the SIM card when the product is in power saving mode.
Introduction to Modem Operation-The AT Command Set RC3000A modules are used to originate or answer telephone calls and establish links with other devices for the purpose of transmitting voice, data, or fax information between two locations. Please refer to the SIM900 AT Command Manual for complete AT command listings and information After installation, you will now be able to communicate with the modem and establish connections with remote devices.
6 7 AT+CSCS AT+CIMI 8 9 10 11 AT+GCAP AT+CATR A/ AT+CFGRI identification. Select TE character set. Request international mobile subscriber identity. Request overall capabilities. Configure URC destination interface. Repeat last command. Indicate RI when using URC. B.
28 AT+CPCM 29 30 AT+CPCMFMT AT+CPCMREG 31 32 33 AT+VTD AT+CODEC AT+CVOC External PCM codec mode configuration. Change the PCM format. Control PCM data transfer by diagnostics port. Tone duration. Set audio codec mode. Get the current vocoder capability in a call. C.
D. Network Service Related Commands 1 2 3 4 5 Syntax AT+CREG AT+COPS AT+CLCK AT+CPWD AT+CLIP 6 AT+CLIR 7 AT+COLP 8 9 AT+CCUG AT+CCFC 10 11 12 AT+CCWA AT+CHLD AT+CUSD 13 14 15 16 17 18 19 20 21 22 23 24 AT+CAOC AT+CSSN AT+CLCC AT+CPOL AT+COPN AT+CNMP AT+CNBP AT+CNAOP AT+CNSDP AT+CPSI AT+CNSMOD AT+CTZU 25 26 27 28 29 30 AT+CTZR AT+CCINFO AT+CSCHN AT+CSRP AT+CRUS AT+CPLMNWLIST 31 32 33 AT+CPASSMGR AT+CNSVSQ AT+CNSVS Expect Result Description Network registration. Operator selection.
34 AT+CNSVN 35 AT+CNSVUS 36 AT+CNSVUN 37 AT+CCGMDF 38 39 AT+CPLMNPASS AT*CNTI Network full band scan in numeric format. Network band scan by channels in string. Network band scan by channels in numeric. Enable single mode in RAT balancing mode. Manage PLMN filter password. Query Network Mode. E.
3 4 5 AT+CRSM AT+SPIC AT+CSPN 6 AT+CRFSIM Restricted SIM access. Time remain to input SIM PIN/PUK Get service provider name from SIM. Reinitialize the SIM card. G.
28 29 AT+CDCDMD AT+CDCDVL 30 31 AT+CBC AT+CDTRISRMD 32 AT+CDTRISRS 33 AT+CGFUNC 34 35 AT+CGWHOST AT+CGWISRMD 36 37 38 39 40 AT+CKGSWT +KEY AT+CUSBSPD AT+CLEDITST AT+CADCA 41 42 43 44 AT+CAPWRON AT+CAPWROFF AT+CBVTBP AT+CRFOP Set DCD pin mode. Set DCD pin high-low in GPIO mode. Battery charge. Configure the trigger condition for DTR’s interrupt. Enable/Disable the pin of DTR’s awakening function. Enable/Disable the function for the special GPIO. Reset GPIO 41 to high level.
6 AT+CEMNLIST Set the list of emergency number. J. File System Related Commands 1 2 Syntax AT+FSCD AT+FSMKDIR 3 4 AT+FSRMDIR AT+FSLS 5 6 7 8 9 10 AT+FSDEL AT+FSRENAME AT+FSATTRI AT+FSMEM AT+FSLOCA AT+FSCOPY Expect Result Description Select directory as current directory. Make new directory in current directory. Delete directory in current directory. List directories/files in current directory. Delete file in current directory. Rename file in current directory. Request file attributes.
7 8 9 10 11 AT&V AT&D AT&S ATV AT&F Display current configuration. Set DTR function mode. Set DSR function mode. Set result code format mode. Set all current parameters to manufacturer defaults. M. Commands for Packet Domain 1 2 3 4 Syntax AT+CGDCONT AT+CGDSCONT AT+CGTFT AT+CGQREQ 5 AT+CGEQREQ 6 AT+CGQMIN 7 AT+CGEQMIN 8 9 10 11 12 13 14 15 AT+CGATT AT+CGACT AT+CGDATA AT+CGPADDR AT+CGCLASS AT+CGEREP AT+CGREG AT+CGSMS 16 AT+CGAUTH Expect Result Description Define PDP Context.
5 AT+CGSOCKEQREQ 6 AT+CGSOCKQMIN 7 AT+CGSOCKEQMIN 8 9 10 11 12 13 14 15 16 17 18 19 AT+IPADDR AT+NETOPEN AT+TCPCONNECT AT+TCPWRITE AT+UDPSEND AT+SERVERSTART AT+LISTCLIENT AT+CLOSECLIENT AT+ACTCLIENT AT+NETCLOSE AT+CIPHEAD AT+CIPSRIP 20 21 AT+CIPCCFG AT+CIPOPEN 22 23 AT+CIPSEND AT+CIPCLOSE 24 AT+CDNSGIP 25 AT+CDNSGHNAME 26 27 AT+CIPMODE AT+CIPSTAT 28 AT+CTCPFIN 29 30 31 32 33 AT+CENDUPPDP AT+CTCPKA AT+CPING AT+CPINGSTOP AT+CTEUTP 34 AT+CUPURE 35 36 37 AT+CINICMPALLOW AT+TCPCLOSE Info
related to TCP/IP O. SIM Application Toolkit (SAT) Commands 1 2 3 4 Syntax AT+STIN AT+STGI AT+STGR AT+STK Expect Result Description SAT Indication. Get SAT information. SAT respond. STK switch. P. Internet Service Commands P-1 Simple Mail Transfer Protocol Service 1 Syntax AT+SMTPSRV 2 3 4 AT+SMTPAUTH AT+SMTPFROM AT+SMTPRCPT 5 6 7 8 9 10 AT+SMTPSUB AT+SMTPBODY AT+SMTPBCH AT+SMTPFILE AT+SMTPSEND AT+SMTPSTOP Expect Result Description SMTP server address and port number.
10 the session. Read an e-mail from file system. AT+POP3READ P-3 File Transfer Protocol Service 1 2 3 4 Syntax AT+CFTPPORT AT+CFTPMODE AT+CFTPTYPE AT+CFTPSERV 5 6 7 8 AT+CFTPUN AT+CFTPPW AT+CFTPGETFILE AT+CFTPPUTFILE 9 AT+CFTPGET 10 11 AT+CFTPPUT AT+CFTPLIST 12 AT+CFTPMKD 13 14 15 AT+CFTPRMD AT+CFTPDELE Unsolicited FTP Codes (Summary of CME ERROR Codes) Expect Result Description Set FTP server port. Set FTP mode. Set FTP type. Set FTP server domain name or IP address.
7 Unsolicited HTTPS Codes P-6 Secure File Transfer Protocol Service 1 2 3 4 5 Syntax AT+CFTPSSTART AT+CFTPSSTOP AT+CFTPSLOGIN AT+CFTPSLOGOUT AT+CFTPSMKD 6 7 8 AT+CFTPSRMD AT+CFTPSDELE AT+CFTPSCWD 9 AT+CFTPSPWD 10 11 AT+CFTPSTYPE AT+CFTPSLIST 12 13 AT+CFTPSGETFILE AT+CFTPSPUTFILE 14 AT+CFTPSGET 15 16 17 AT+CFTPSPUT AT+CFTPSSINGLEIP Unsolicited FTPS Codes Expect Result Description Acquire FTPS protocol stack. Stop FTPS protocol stack. Login the FTPS server. Logout the FTPS server.
2 3 4 AT+CSSLSTOP AT+CSSLOPEN AT+CSSLCONT 5 6 7 AT+CSSLCLOSE AT+CSSLSEND AT+CSSLSET 8 AT+CSSLMODE 9 Unsolicited common SSL Codes Stop common SSL stack. Connect to server using SSL. Continue to connect to server in ALERT state. Disconnect from server. Send data to server. Set the parameter of common SSL function. Set the mode of common SSL function. Q.
22 23 AT+CMMSUA AT+CMMSPROFILE 24 Supported Unsolicited Result Codes in MMS Indication of Sending/Receiving MMS Summary of CME ERROR Codes for MMS 24.1 24.2 Set the User-Agent of MMS packet. Set the User-Agent profile of MMS packet. R. CSCRIPT Commands 1 2 3 4 5 6 7 Syntax AT+CSCRIPTSTART AT+CSCRIPTSTOP AT+CSCRIPTCL AT+CSCRIPTPASS AT+CSCRIPTCMD AT+PRINTDIR Expect Result Description Start running a LUA script file. Stop the current running LUA script. Compile a LUA script file.
14 15 16 AT+CGPSXE AT+CGPSXD AT+CGPSXDAUTO 17 18 19 AT+CGPSINFOCFG AT+CGPSPMD AT+CGPSMSB 20 AT+CGPSHOR 21 Unsolicited XTRA download Codes Cell Assistant Location 22 22.1 22.2 22.3 22.4 Enable/disable GPS XTRA function. Download XTRA assistant file. Download XTRA assistant file automatically. Report GPS NMEA-0183 sentence. Configure positioning mode. Configure based mode switch to standalone. Configure positioning desired accuracy.
V. OTAD Commands 1 Syntax AT+COTADPHONE NUMBER Expect Result Description Modify OTAD phone number. W.
Limited Warranty Warranty Coverage and Duration Radicom Research, Inc. (“RRI”) warrants to the original purchaser its RRI-manufactured products (“Product”) against defects in material and workmanship under normal use and service for a period of one year from the date of delivery. During the applicable warranty period, at no charge, RRI will, at its option, either repair, replace or refund the purchase price of this Product, provided it is returned in accordance with the terms of this warranty to RRI.
(b) Defects or damage from misuse, accident or neglect. (c) Defects of damage from improper testing, operation, maintenance, installation, alteration, modification or adjustment. (d) Disassembly or repair of the Product in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. (e) Any Product that has had its serial number or date code removed or made illegible.
Contacting Radicom Research If more information or technical support is needed, please contact us: 2148 Bering Drive San Jose, CA. 95131 Telephone: (408) 383 9006 Fax: (408) 383 9007 or e-mail: sales@radi.com http://www.radi.