INSTALLATION, AND MAINTENANCE MANUAL FOR GAS FIRED, ONLY HEATING WALL-HUNG BOILERS (SYSTEM BOILERS) Model RS 20 E - RS 24 E - RS 30 E TYPE C ROOM SEALED CE 0063 - 0694 Technical Specification RADIANT BRUCIATORI S.p.A.
INDEX INSTALLATION INSTRUCTIONS AND WARNINGS page 1 TECHNICAL DATA page 2 OVERALL DIMENSIONS - EXHAUST FLUE SYSTEM page 3-4 GENERAL INSTALLATION REQUIREMENTS page 5 BOILER INSTALLATION page 7 ELECTRICAL CONNECTIONS page 9; 15-16 BOILER CONTROL PANEL page 10 STARTING UP THE BOILER FOR THE FIRST TIME page 10 REGULATING THE GAS PRESSURE page 12 MULTIGAS OPERATION page 13 MAIN COMPONENTS page 14 MAINTENANCE page 17 UNPACKING page 17 FAULT FINDING CHART page 18 SHORT LI
Installation Manual THE FRIENDLY POWER OF HEAT Thank you for choosing RADIANT Declaration for purposes of Art. 7 of Law 46 of 5 April 1990. RADIANT BRUCIATORI S.p.A. hereby declares that all of its products are constructed to industry standards as required by the Article in question and by Article 5 of the law in effect (D.P.R. no. 447/97). RADIANT BRUCIATORI S.p.A. products are type tested EC. All RADIANT boilers are constructed according to UNI - CIG (EC) norms.
Installation Manual TECHNICAL DATA Type C devices are devices in which the combustion circuit (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed. CENTRAL HEATING sealed combustion circuit type C32 Coaxial vertical C12 Coaxial horizontal C52 Double Technical data MODELS Maximum rated input KCal/h Kw BTU/hr KCal/h Kw BTU/hr KCal/h Kw BTU/hr KCal/h Kw BTU/hr bar bar bar °C Litres mm. mm. mm. Kg.
Installation Manual TYPE C WALL-MOUNTED BOILERS SEALED COMBUSTION CIRCUIT: = 100 = 60 100 60 450 870 Kit A. Horizontal coaxial exhaust flue system with 360° rotation. It allows the flue exhaust and the air intake directly to an external wall. . N.B.: To insert a bend in the flue, reduce total flue length by 0.8 m. F 125 320 80 101 46 80 51 101 A 182 790 948 24 R G 51 101 F A Kit B. Double exhaust/emission twin flue system with 360° rotation.
TYPE C WALL-MOUNTED BOILERS SEALED COMBUSTION CIRCUIT: 80 125 80 125 Installation Manual 790 Kit G. Horizontal coaxial exhaust flue system with 360° rotation. It allows the flue exhaust and the air intake directly to an external wall. . N.B.: To insert a bend in the flue, reduce total flue length by 0.8 m. G F 125 320 80 101 46 80 51 101 A 80 R 24 17 790 182 182 790 790 120 R RETURN ¾” G GAS 1/2" F COLD WATER INLET 1/2" A HEATING FLOW ¾” 17 24 R G 51 101 F A Kit B.
Installation Manual GENERAL INSTALLATION REQUIREMENTS GAS SAFETY It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with.
Installation Manual FLUE POSITION IMPORTANT: THE FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN BS 5440:1. The boiler MUST be installed so that the terminal is exposed to the external air. It is important that the position of the terminal allows free passage of air across it at all times. If the terminal discharges into a pathway or passageway check that combustion products will not cause nuisance and that the terminal will not obstruct the passageway.
Installation Manual BOILER INSTALLATION - MINIMUM DISTANCES FOR FIXING TO WALL To allow access inside the boiler for maintenance operations, the minimum distances shown in fig. 2 must be kept. 60 450 60 100 60 = 118 80 125 320 max. 3000 790 870 24 17 790 894 450 182 MINIMUM DISTANCES IN mm. 80 80 KIT B 182 120 17 790 924 790 948 60 100 = 80 To aid installation, the boiler is supplied with a template (see fig. 1) for advance location of connections to pipes.
Installation Manual GAS CONNECTIONS The gas supply must be connected up by a corgi registered fitter.
Installation Manual ELECTRICAL CONNECTIONS The boiler works with 230 V 50 Hz AC current and has maximum input of 150 W. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm. Make sure the live and neutral connections conform to the diagram. A secure earth connection is compulsory. Fig. 1 NOT APPLICABLE FOR U.K.
Installation Manual INSTRUMENT PANEL 3 2 1 LEGEND (see fig. 1) 1. SUMMER-WINTER ON-OFF SWITCH 2. HEATING TEMPERATURE ADJUSTMENT KNOB 3. SPACE FOR ADDING AN OPTIONAL TIMER SELF- DIAGNOSTIC LEGEND (see fig. 2) 4. WARNING: LACK OF WATER IN THE SYSTEM 5. WATER PRESSURE LEVEL 1 BAR 6. WATER PRESSURE LEVEL 1.5 BAR 7. WARNING: CHIMNEY SAFETY DEVICE ON R OPEN CHAMBER MODEL 8. WARNING: LOCK-OUT INDICATOR (FIXED LIGHTS ONLY – NO FLASHING) Fig. 1 ELECTRONIC WATER PRESSURE GAUGE 4 5 6 0.5 1 1.5 7 Fig.
Installation Manual • check the pressure in the system: if this has gone down, restore it until the pressure gauge shows 1.5 bar. Close the tap on the filling loop once this operation is completed; STARTING UP THE BOILER • open the gas cock; • turn on the boiler; • set the selector to winter; • make sure that 5 and 6 light are ON (fig.2 pag.10) on the boiler panel. If light no. 4 is ON, it means water deficiency in the system: fill the system until a pressure of 1,5 bar has been reached (light no.
Installation Manual REGULATING THE MAX. AND MIN. MODULATION GAS PRESSURE A To regulate the maximum gas pressure to the burner proceed as follows: • insert a gauge into the pressure socket B (fig.1). • remove the aluminium protective cap from screw A (fig.1) counter-clockwise; • turn the boiler on with the selector turned to the winter position; • once ignited, set the "P1 MAX. HEAT" trimmer (fig.2) to the maximum and turn screw A (fig.
Installation Manual GAS TYPE CONVERSION GAS BURNER UNIT 1 Conversion of the boiler from natural gas to LPG and vice versa must be performed by qualified personnel only. Conversion is performed as follows: d) e) turn off the main power switch; close the gas cock; substitute the jets on the main burner as follows: undo the gas pipe 5 (fig.
Installation Manual mod. RS 30 E mod. RS 20 E - RS 24 E 14 14 15 15 3 2 3 16 2 6 1 5 2 10 10 13 13 2 8 9 3 4 7 7 12 11 12 5 11 KEY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. MAIN HEAT EXCHANGER 20.000 – 24.000 kCal/h MAIN HEAT EXCHANGER 30.000 kCal/h CIRCULATING PUMP RSL 15/5 CIRCULATING PUMP RSL 15/6 GAS VALVE VK4105 LT.6 EXPANSION VESSEL 3 BAR SAFETY VALVE BURNER 13 R. BURNER 17 R.
Installation Manual ELECTRONIC PRINTED CIRCUIT BOARD SM 20013 + CONNECTORS Room sealed M3 M2 M1 M4 M7 M6 M5 ER 3 12 11 10 9 black 7 8 9 black-blue brown SR blue 2 black CIRUIT BOARD S4565QM 1012 C PAC TF 1 EA 8 7 6 5 4 3 2 + 1 - TS M2 M3 10 11 12 13 14 15 27 - SUMMER-WINTER SWITCH - ROOM THERMOSTAT - TIME CLOCK - IGNITION ELECTRODE - IONISATION ELECTRODE - AIR PRESSURE SWTICH - FAN 26 25 23 24 22 M5 brown E.I.
SYSTEM BOILER – Cod. 99951NA – November 2002 16 M7 32 M5 24 TL MF PWM T. AMB. E/I T. OFF SPIA PRIORITY BLOCK AND GPL-MET TERM. FUMI HIGT VOLTAGE CIRCUIT (220V AC) C3 M5 26 M5 27 THERMOSTATS MODULATION BLOCK SPIA RV EV LB R8 M7 30 8 7 6 5 4 3 D6 M7 33 no 12 11 10 9 M7 35 c SENSOR R6 nc HOT WATER R10 RV-C M7 34 M5 25 MAX HEAT. M6 28 M7 36 PF MIN. GAS C M6 29 RP-C M7 31 RT-C T. HEAT. ALLAR. H2O M4 16 M4 17 F T. SAN.
Installation Manual MAINTENANCE To keep the boiler in efficient and safe operating condition, we recommend that the following checks are performed at least once a year (according to reference standards): • • • • • • • • • Check all seals on the gas components and replace gaskets to restore perfect seal as required. Check all seals on the water components and replace gaskets to restore perfect seal as required.
Installation Manual SHORT LIST SYSTEM BOILER – Cod.
USER MANUAL Model RS 20 E / 40 - 60 TYPE C Model ROOM SEALED RS 24 E / 70 - 90 TYPE C ROOM SEALED TA02B101.B1203 Technical Specification RADIANT BRUCIATORI S.p.A.
User Manual BOILER OPERATION AND ADJUSTMENT PROCEDURES FOR USERS Before turning on the boiler read the following warnings carefully . Make sure that the warranty booklet carries the stamp of the CORGI registered technician (you can check this by contacting corgi on 01256.372200) responsible for installing the boiler. Installation, starting up for the first time, adjustments and maintenance operations must all be carried out solely by qualified technicians.
RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • Internet: http://www.radiant.it UK – Radiant Helpline – 01329.828555 ALL DESCRIPTIONS AND ILLUSTRATIONS CONTAINED IN THIS LEAFLET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET. E + OE ALL RIGHTS RESERVED.