Technical data

SERVICING
AND
MAINTENAN
CE
INSTRUCTIONS
_
CONDENSING WALL-HUNG BOILER TG05A052.A0205
33
GAS DATA TABLE
models: RH 28 RHR 28
Natural Gas
G 20
Liquid Butane Gas
G 30
Liquid Propane Gas
G 31
Lower Wobbe index (15°C; 1013 mbar)
MJ/Nm
3
45.67 80.58 70.69
Rated feed pressure mbar 20 30 37
Minimum feed pressure mbar 17 28 28
Main burner: 13 Jets - Ø jet mm 1.25 0.77 0.77
Consumption
(15°C; 1013 mbar)
m
3
/h 2.84 - -
Consumption (15
°C; 1013 mbar)
kg/h - 1.78 1.71
GAS PRESSURE SETTING
SLOW IGNITION ADJUSTMENT
This is a slow ignition regulator whose trimmer is factory set to the
minimum.
For adjustment proceed as follows:
if turned clockwise the gas pressure at the burner increases on ignition
while turning counter-clockwise decreases the gas pressure.
ANTI CYCLING DEVICE
This allows the various ignitions to be delayed once the boiler has
reached the optimum temperature.
The time range goes from 0 up to 7.5 minutes.
NATURAL GAS G20 LIQUID BUTANE GAS G 30 LIQUID PROPANE GAS G31
min. max. max min. max. min.
2.15 11.4 27.8 5.45 35.5 7.35
Fig. 1