6.8 Diagnostics
Error codes:
IONISATION BLOCK
SAFETY THERMOSTAT TRIPPED
WATER PRESSURE ALARM
HEATING SENSOR MALFUNCTION
D.H.W. SENSOR MALFUNCTION
GENERAL ALARM (AIR PRESSURE SWITCH OR WATER PRESSURE SWITCH)
PARAMETER PROGRAMMING REQUEST
Signal codes
SIGNAL CODE
SIGNAL TYPE
DESCRIPTION
CHIMNEY-SWEEP
FUNCTION ACTIVE
PRESSING THE “SERVICE” BUTTON FOR 5 SECONDS
ACTIVATES THE CHIMNEY-SWEEP FUNCTION. PRESSING THE
BOILER OFF BUTTON DEACTIVATES THE FUNCTION.
THE CHIMNEY-SWEEP FUNCTION OPERATES THE BOILER AT
MAXIMUM HEATING PRESSURE FOR 15 MINUTES WITHOUT
ANY MODULATION. THE FUNCTION IS USEFUL FOR
COMBUSTION TESTING.
HEATING ANTI-
FREEZE FUNCTION
THE FUNCTION IS ACTIVATED WHEN THE HEATING SENSOR
SENSES A TEMPERATURE OF 5 °C. THE BOILER OPERATES
AT MINIMUM GAS PRESSURE WITH THE DIVERTER VALVE IN
THE WINTER POSITION. THE FUNCTION IS DEACTIVATED
WHEN THE TEMPERATURE DETECTED BY THE SENSOR
REACHES 30 °C.
D.H.W ANTI-FREEZE
FUNCTION
THE FUNCTION IS ACTIVATED WHEN THE SENSOR SENSES A
TEMPERATURE OF 4 °C. THE BOILER OPERATES AT MINIMUM
GAS PRESSURE. THE DIVERTER VALVE CLOSES IN THE
SUMMER POSITION AND HEATS THE D.H.W CIRCUIT. THE
FUNCTION IS DEACTIVATED WHEN THE D.H.W SENSOR
DETECTS A TEMPERATURE OF 8°C.
INCOMPATIBLE
REMOTE CONTROL.
THE FUNCTION IS ACTIVATED WHEN A RADIANT REMOTE
CONTROL OR INTERFACE BOARD IS NOT PRESENT.